pre-insulated end caps for ducts with gaskets IF-ESS

Construction:

  • Made of galvanized steel
  • With EPDM sealing gaskets
  • Covered with flexible elastomer foam (FEF) insulation
  • Insulation material meets class B fire safety standards
  • System elements meet D-class airtightness standard

 

Installation:

  • Easy installation
  • Saves installation time and space
  • Ensures material savings

 

Operating temperature: -40°C ... +85°C
Insulation thickness [mm]: 9
Dimensions [mm]: Ø100; Ø125; Ø160; Ø200
Colors: Black

 

 

Isolated metal air duct caps from EUROPLAST are designed for ventilation, air conditioning, and heat recovery systems with additional requirements for energy efficiency. The applied insulation provides excellent sound insulation, thermal insulation, and protection against condensation formation. The material used complies with Class B fire safety standards. Factory-applied insulation significantly reduces installation time and resources at the site, as well as ensures the quality of insulation.

Connection

Class

Sort by

Article Description EAN Connection Class
IF09-ESS100
IF09-ESS100
pre-insulated end cap metal, Ø100mm with gaskets, isolation 9mm
4750492029985
Ø 100 mm B; D
IF09-ESS125
IF09-ESS125
pre-insulated end cap metal, Ø125mm with gaskets, isolation 9mm
4750492029978
Ø 125 mm B; D
IF09-ESS160
IF09-ESS160
pre-insulated end cap metal, Ø160mm with gaskets, isolation 9mm
4750492029992
Ø 160 mm B; D
IF09-ESS200
IF09-ESS200
pre-insulated end cap metal, Ø200mm with gaskets, isolation 9mm
4750492030004
Ø 200 mm B; D
 

     

 

Type ØDnom
[mm]
T
[mm]
m
[kg]
IF09-ESS100 100 9 0,11
IF09-ESS125 125 9 0,16
IF09-ESS160 160 9 0,23
IF09-ESS200 200 9 0,32
 
 
 
 
Essential characteristics Performance properties Testing standards
Thermal conductivity coefficient
(for all thicknesses)
-10°C - 0,034 W/m × K
0°C - 0,036 W/m × K
25°C - 0,037 W/m × K
40°C - 0,041 W/m × K
EN 12667
Reaction to fire B-s3, d0 EN 13501-1
Operating temperature -40°C ... +85°C